TITANUS®
Early detection is necessary for possible fire suppression - this decides the amount of damage. To support this, WAGNER has placed its confidence in early smoke detection systems.
WAGNER smoke detection systems use optical systems. Point-type detectors can be limited in their function, so WAGNER uses its patented air sampling smoke detection systems - which can provide very high sensitivity detection from a small smoke sample.
Many application problems have already been successfully solved using air sampling. For many years WAGNER has been an international leader in fire detection using air sampling smoke detection systems.
WAGNER offers a variety of products for both room and equipment monitoring - guaranteeing a bespoke system for a specific application and for every available budget.
Advantages at a Glance
- Innovative detection technology using a newly developed High-Power-Light-Source
- A detector module specially developed for use with air sampling smoke detection systems
- Ordinary commissioning and maintenance
- VdS approved
- Provided with LOGIC·SENS intelligent signal processing
- Innovative air flow sensor and closed circuit air path
- User operated diagnostic tool provides fast and simple servicing
Download PDF >
.......................................................................................................................................................................
TITANUS PRO·SENS®
Universal air sampling smoke detection. Provided with LOGIC·SENS intelligent signal processing.
TITANUS PRO-SENS® Performance Characteristics
- Potential free relay outputs for alarm- and fault signalling to house fire alarm system
- One or two detection zones
- Up to 64 air sampling points per system possible, maximum pipe length 560 metres
- Monitored area air sampling point is the same as a point-type detector (depending on operating mode)
- True coincidence detection possible
- Sensitivity range up to 0.015 %/m light obscuration
- Optional networking ability
Download PDF >
..........................................................................................................................................................................
TITANUS TOP·SENS®
Sensitive smoke sampling system with graded alarm and bar graph display.
Provided with LOGIC·SENS intelligent signal processing.
TITANUS TOP·SENS® Performance Characteristics
- Potential free relay outputs for alarm and fault signalling to house fire alarm system
- 10-level alarm display with activating thresholds for alert, action and fire-alarm
- Sensitivity range up to 0.0015 %/m light obscuration
- Optional networking ability
- True coincidence detection possible
- One or two detection zones
- Up to 64 air sampling points per system possible, maximum pipe length 560 metres
- Monitored area air sampling point is the same as a point-type detector (depending on operating mode)
Download PDF >
..........................................................................................................................................................................
TITANUS MICRO·SENS®
Smoke detection system based on state-of-the-art technology designed for universal implementation in a wide range of applications.
It can also be applied in difficult environments thanks to its intelligent signal processing.
Covers an area up to 400 m². The source of the fire can be identified when monitoring a maximum of five rooms.
TITANUS MICRO·SENS® Performance Characteristics
- Identification of the source of fire by ROOM·IDENT
- False alarm protection by intelligent signal processing LOGIC·SENS
- Simple installation, start-up by Plug & Play
- Quick and easy commissioning and maintenance
- Very early fire detection by High-Power-Light-Source
- Safe monitoring of the pipe system by PIPE·GUARD
- Single hole fault monitoring equivalent to point type detection
Download PDF >
..........................................................................................................................................................................
TITANUS SUPER ·SENS®
Highly sensitive smoke sampling system for earliest possible detection of even the smallest initial fires.
Monitoring high air speed climatic ducts possible.
TITANUS SUPER ·SENS® Performance Characteristics
- Potential free relay outputs for alarm and fault signalling to house fire alarm system
- Sensitivity range up to 0.0025 %/m light obscuration
- Up to 24 air sampling points per system possible, maximum pipe length 360 metres
- Monitored area air sampling point is the same as a point-type detector (depending on operating mode)
- 10-level alarm display with activating thresholds for alert, action and fire-alarm
- Clean-room variety with higher sensitivity available
- Optional networking ability
.........................................................................................................................................................................
TITANUS RACK-SENS®
Highly sensitive aspirated smoke detection system for very early warning of even the smallest incipient fires.
482,6 mm construction (19'') model for use in EDP, server and switch cabinets.
TITANUS RACK-SENS® in detail
- Integrated system for fire detection and protection
- Affordable monitoring of up to 5 cabinets with a single system
- Up to 400 times more sensitive than conventional fire detectors
- High immunity to false alarms via fire pattern recognition
- Individual adjustment of response
- Maintenance with interactive diagnosis means no interruption of operations
- Central monitoring, remote diagnosis and remote maintenance by networking
- Optional use of second detector module for dual detector voting
- Fire detection and extinguishing in a single device (88,9 mm construction height (2U))
- Choice of extinguishing gases:
44,45 mm construction height (1U) device with external extinguishing: Novec 1230, FM-200, Nitrogen, Argon or Carbon Dioxide. 88,9 mm construction height (2U) device with built-in extinguishing: Novec 1230, FM-200
Download PDF >
........................................................................................................................................................................
VisuLAN T®
Visibility of all systems with status and diagnostic information at central location.
Easy operation with clear and uniform display of status and incident reports.
Ethernet BUS systems with TCP/IP protocol.
VisuLAN T® Performance Characteristics
- Effective support of the alarm process with the help of clear procedure instructions
- Reliable documentation of event procedures
- Information about faults, smoke concentration and airflow with history is available
- Printout of protocols, graphics and data export
|